Raisecom Technology Co., Ltd
24
6.2. Front panel explanation:
Front view:
6.2.1. Globle indicator lights:
SYSgreen: Indicates system work status. Flicking: system works normal. ON: 1 CUP
works abnormal; 2 system configuration error or the following problems:
1User-board communicates abnormally
2Temperature sensor works abnormally
3Fan does not work
4Time slots configuration error
OFF: CPU works abnormally
PWRgreen: OFF system is not powered on
TXgreen: ON serial interface is transmitting data
RXgreen: ON serial interface is receiving data
6.2.2. Indicator lights of line-board:
4E1green: ON line-board is 4E1 interface card
2E1green: ON line-board is 2E1 interface card
OPTgreen: ON line-board is optical interface card
Note: only one of the three lights can be ON, otherwise there is system error.
6.2.3. Optical interface alarm indicator lights:
Optical interface alarm indicator lights form a matrix, L and R indicate local and remote,
OPLOS,LOF , E-3, E-6indicate alarms:
L OP LOSred: Loss of signal at local
L OP LOFred: Loss of frame at local
L E1 E-3red: Alarm when bit error ratio is more than 10
-3
/s at local
L E1 E-6red: Alarm when bit error ratio is more than 10
-6
/s at local
R OP LOSred: Loss of signal at remote
R OP LOFred: Loss of frame at remote
Figure 17