Masterclock TCR1000 Manual do Utilizador Página 13

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 23
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 12
TCR1000SDKRev.3.0.0  Page13
TCR1000_ApiClearEnhanced
TheTCR1000_ApiClearEnhancedfunctionforcesoffallenabledenhancedinterruptfeaturesonthe
TCR1000
timecodereadercard.
BOOLTCR1000_ApiClearEnhanced(void)
Parameters
Thisfunctionhasnoparameters.
ReturnValues
ReturnsTRUEifallenhancedfeaturesclearedsuccessfully.ReturnsFALSEifunabletoclearenhanced
features.
Remarks
UseofthisfunctiondefiesthemultithreadsafecapabilityofthisAPIandisnotrecommendedforuse
inanenvironmentwheremultipleapplicationswillusetheasynchronousnotifications.
TCR1000_ApiRequestRecalibration
TheTCR1000_ApiRequestRecalibrationfunctionforcestheTCR1000cardtorecalibratethe
automaticgaincontroltotheincomingtimecode’ssignallevel.
BOOLTCR1000_ApiRequestRecalibration(void)
Parameters
Thisfunctionhasnoparameters.
ReturnValues
ReturnsTRUEifrecalibrationstartedsuccessfully.
Remarks
OncetheTCR1000cardhasdetectedthetimecodeformatandcalibrated
itsgainleveltothetime
code’ssignallevelitwillexpectthatleveltoremainconstant.Ifthetimecodeformatchangesorthe
levelfluctuates,thecardmayceasetodecodetimecodeproperly.Inasituationwherealevelchange
isanticipated,suchasaswitchtoadifferenttimecodefeed,thisAPIinstructstheTCR1000to
recalibratethegain.
ThisfunctioncanbeusedtoswitchbetweenSMPTEandIRIGBtimecodes.
Vista de página 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 22 23

Comentários a estes Manuais

Sem comentários